Testing Range |
Description |
Impedance |
50Ω |
Test Port Connector |
N-type, female |
Number of Test Port |
2 |
Frequency Range |
1MHz to 6.5GHz |
Low Noise Level |
< -120dBm (IFBW=10 Hz) |
Frequency Accuracy |
5ppm |
Frequency Resolution |
10Hz |
Number of Measurement Points |
2 to 10001 |
Measurement Bandwidths |
1Hz to 50kHz |
Dynamic range (IFBW 10Hz) |
117dB, typ.121 dB |
Measurement parameters |
S11, S21, S12, S22 |
Testing Accuracy |
|
Transmission Measurement Accuracy (magnitude/phase) |
|
+5 dB to +10 dB |
0.2dB/2º |
-50 dB to +5 dB |
0.1dB/1º |
-70dB to -50dB |
0.5 dB/3º |
-90dB to -70dB |
2.5 dB/8º |
Reflection Measurement Accuracy(magnitude/phase) |
|
-15dB to 0dB |
0.4dB/3º |
-25dB to -15dB |
1.0dB/6º |
-35dB to -25dB |
3.0dB/20º |
Trace stability |
|
Trace noise magnitude (IF bandwidth 3kHz) |
10 mdB rms |
Temperature Dependence (per one degree of temperature variation) |
0.02dB |
Effective System Data① |
|
Effective Directivity |
42 dB |
Effective Source Match |
40 dB |
Effective Load Match |
42 dB |
①Applied over them temperature range of 23°C ± 5°C after 40 minutes of warming-up, with less than 1°deviation from the full two-port calibration temperature, at output power of -5dBm and IF bandwidth 10Hz.
Test port output |
Description |
Match(W/O system error correction) |
18 dB |
Power Range |
-50 dBm to +5 dBm |
Power Accuracy |
±1.5 dB |
Power Resolution |
0.05dB |
Test port input |
|
Match(W/O system error correction) |
18 dB |
Max Input Level |
+23 dBm |
Max Input Voltage |
+35 V |
Noise level |
-120 dBm |
General Data |
|
External Reference Input |
SMA female; 10 MHz; 2 dBm ± 3 dB |
External Reference Output |
SMA female; 10 MHz; 3 dBm ± 2 dB |
Operating Temperature Range |
+5°C to +40°C |
Storage Temperature Range |
-45°C to +55°C |
Operating Humidity |
90% (25°C) |
Operating Atmospheric Pressure |
84 to 106.7 kPa |
Calibration Interval |
3 years |
Power Supply |
110/220 ± 22 V (AC), 50 Hz |
Power Consumption |
18W |
Dimensions(W x H x D) mm |
180x50x290 |
Weight |
2.3kg |
Guarantee |
1year |
Model |
Description |
T6 |
2 port USB vector network analyzer (1MHz to 6.5GHz) |
Option |
Description |
T6/TW-1 |
Extention guarantee to 3 years |
Comparision between VNA modules |
|||
|
Transcom T6 |
Tektronix TTR500 |
Copper Mountain S5048 |
Frequency Range |
1MHz to 6.5GHz |
100kHz to 3GHz 100kHz to 6GHz |
20kHz to 4.8GHz |
Dynamic Range(IFBW 10 Hz) |
117dB |
122dB |
120dB |
Trace Noise (dBrms) |
0.01 |
0.008 |
0.002 |
Output Power |
-30/-50 to +5 dBm |
-50 to +7 dBm |
-50 to +5 dBm |
Measurements |
S11,S12,S21,S22 |
S11,S12,S21,S22 |
S11,S12,S21,S22 |
Frequency Resolution |
10Hz |
1Hz |
10Hz |
Frequency Accuracy |
±5ppm |
±7ppm |
±5ppm |
Cancer Detection
T6 USB VNA is customized for the Southern Medical University and is used to detect cancer cell.

System Intergration
Italy customers intergrated T6 into their antenna test system to test S parameters of antenna.